P250H-3

OVERVIEW

225 to 330 kVA Diesel Generator Sets. As your power needs increase, this cost effective generator set range delivers a powerful performance with world class power density. Compact and durable, they can easily be manoeuvred into position, whatever the installation conditions.

GENERATOR SET SPECIFICATIONS

Minimum Rating 230.0 kVA / 184.0 kW
Maximum Rating 265.0 kVA / 212.0 kW
Voltage 110-480 Volts
Frequency 50 Hz or 60 Hz
Speed 1500 or 1800 RPM
50 Hz Prime 230.0 kVA / 184.0 kW
50 Hz Standby 250.0 kVA / 200.0 kW
60 Hz Prime 240.0 kVA / 192.0 kW
60 Hz Standby 265.0 kVA / 212.0 kW

GENERATOR SET CONFIGURATIONS

Emissions/Fuel Strategy Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

ENGINE SPECIFICATIONS

Engine Model Perkins® 1306A-E87TAG4
Compression Ratio 16.9:1
Governor Type Electronic
Bore 116.6 mm (4.6 in)
Stroke 135.9 mm (5.4 in)
Displacement 8.7l (530.9 cu. in)

Features

FG WILSON DIESEL ENGINE

Perkins Engine

ALTERNATOR

Benefiting from a choice of leading alternators, the range incorporates the Marelli alternator as standard across three phase models.

POWER WIZARD 1.1 +

The FG Wilson DCP range allows you to monitor and control your generator set with ease, providing important diagnostic information whilst ensuring your unit operates within safe parameters. FG Wilson DCP digital control panels, provide simple, intuitive menu navigation and control of your generator set operations. Key information is displayed via the LCD screen and LED’s using universally recognised symbols, eliminating the need for complex instructions or language settings.

DESIGN CRITERIA

Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. Standby Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). Standard Reference Conditions Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

SINGLE-SOURCE SUPPLIER

Fully prototype tested with certified torsional vibration analysis available

WORLD WIDE PRODUCT SUPPORT

FG Wilson manufactures product in the following locations: Northern Ireland • Brazil • China • India • USA With headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network

Standard Equipment

P250H-3 STANDARD EQUIPMENT

ENGINE
  • Air Cleaner
  • Lube oil drain valve
  • Engine filled with lubrication oil
  • High Coolant Temperature Shutdown
  • Low Oil Pressure Shutdown
COOLING
  • Coolant Drain Valve
  • Fan, Fan drive and battery charging Alternator drive fully guarded to meet EC Machinery Directive
  • Cooling System filled with Coolant mix
  • Radiator and Cooling Fan
EXHAUST
  • Exhaust stub pipe and gasket
FUEL
  • 8 Hr Fuel Tank
  • Fuel Fittings for Local and Remote Feed
ALTERNATOR
  • Marelli
  • SHUNT Excitation
  • IP23 Protection
  • Coastal Insulation Protection
CONTROL PANEL
  • PowerWizard 1.1+
MOUNTING
  • Base, Formed Steel with Single wall Fuel Tank
  • Certified Base Mounted Lifting Eyes, and Rear Drag Eyelets
  • Battery Tray and Cables

P250H-3 OPTIONAL EQUIPMENT

EXHAUST
  • Industrial, Residential, Critical Silencers
ALTERNATOR
  • Upgrade to Leroy Somer Alternator
  • Quadrature Droop Kit (AR6)
  • Anti-Condensation Heater and Panel Circuitry (AH1)
CONTROL PANELS
  • PowerWizard 2.1 Control Panel (PWT2.1)
  • EasYgen 2500 control panel
STARTING/CHARGING
  • Lead Acid battery (Dry)
GENERAL
  • Upgrade to Standard Set for “CE” Certification
  • Compact Skid Base for Open Sets
  • Sound attenuated, steel or galvanised enclosure
  • Defra bunded fuel tanks (FB4)

*Technical specifications may vary for some products, Please send us an enquiry to receive the updated information.

Our Location

  • Laurus Technologies LLCAl Emadi Business Centre
    Office No. 27, First Floor
    C Ring road
    Doha, Qatar
  • Call Us+974 447 82465

Have A Query?