F125-1

OVERVIEW

Utilising the proven and trusted FG Wilson generator set design, the 8.5 – 290 kVA range provides power that is uncompromising on quality with the introduction of FG Wilson engines and a simplified choice of options. The FG Wilson engines provide reliable power suitable for nonregulated markets or non-mobile applications. Combined with the Marelli alternator, providing coastal insulation protection and a RFI filter as standard, a trusted performance is guaranteed.

GENERATOR SET SPECIFICATIONS

Minimum Rating 115.0 kVA / 92.0 kW
Maximum Rating 137.5 kVA / 110.0 kW
Voltage 220-480 Volts
Frequency 50 / 60 Hz
Speed 1500 / 1800 RPM
50 Hz Prime Rating 115.0 kVA / 92.0 kW
50 Hz Standby Rating 125.0 kVA / 100.0 kW
60 Hz Prime Rating 125.0 kVA / 100.0 kW
60 Hz Standby Rating 137.5 kVA / 110.0 kW

GENERATOR SET CONFIGURATIONS

Emissions/Fuel Strategy Fuel Optimised

ENGINE SPECIFICATIONS

Engine Model FG Wilson FD6-6.5A1
Compression Ratio 17:1
Governor Type Electronic
Bore 105.0 mm (4.1 in)
Displacement 6.5l (396.0 cu .in.)
Stroke 105.0 mm (4.1 in)

Features

FG WILSON DIESEL ENGINE

MARELLI ALTERNATOR

DCP-10 CONTROL PANEL

The FG Wilson DCP range allows you to monitor and control your generator set with ease, providing important diagnostic information whilst ensuring your unit operates within safe parameters. FG Wilson DCP digital control panels, provide simple, intuitive menu navigation and control of your generator set operations. Key information is displayed via the LCD screen and LED’s using universally recognised symbols, eliminating the need for complex instructions or language settings.

DESIGN CRITERIA

Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. Standby Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). Standard Reference Conditions Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

SINGLE-SOURCE SUPPLIER

Fully prototype tested with certified torsional vibration analysis available

WORLD WIDE PRODUCT SUPPORT

FG Wilson manufactures product in the following locations: Northern Ireland • Brazil • China • India • USA With headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network.

Standard Equipment

F275-1 STANDARD EQUIPMENT

AIR INLET
  • Air Cleaner
COOLING
  • Cooling system filled with coolant mix
  • Radiator and Cooling Fan
EXHAUST
  • Exhaust stub pipe & gasket
FUEL
  • 8Hr fuel tank
ALTERNATOR
  • IP23 Protection
CONTROL PANEL
  • DCP-10
MOUNTING
  • Anti-vibration mounts
  • Base, formed steel with single wall fuel tank
  • Certified base mounted lifting eyes, and rear drag eyelets
POWER
  • 3 Pole circuit breaker
GENERAL
  • Generating set is load tested and all protective devices and control functions are simulated and checked

F275-1 OPTIONAL EQUIPMENT

ALTERNATOR
  • Anti-condensation heater
POWER TERMINATION
  • 4 Pole Circuit Breaker
STARTING/CHARGING
  • Lead-Acid Battery (Dry)
GENERAL
  • CE Certification
  • Neutral Earth Link
  • CAL Steel Enclosure
  • CAL Galvanised Enclosure

*Technical specifications may vary for some products, Please send us an enquiry to receive the updated information.

Our Location

  • Laurus Technologies LLCAl Emadi Business Centre
    Office No. 27, First Floor
    C Ring road
    Doha, Qatar
  • Call Us+974 447 82465

Have A Query?